{"product_id":"kyoritsu-kew-2003a-ac-dc-clamp-meter-2003a","title":"KYORITSU KEW 2003A AC\/DC Clamp Meter","description":"\u003ch2\u003eKYORITSU KEW 2003A AC\/DC Clamp Meter\u003c\/h2\u003e\u003cp\u003eProfessional electrical measuring instrument from KYORITSU Japan. The specifications below are based on the manufacturer's 2026 general catalog.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMeasurement of both AC and DC current with transformer jaws of large diameter\u003c\/li\u003e\n\u003cli\u003eCan measure AC and DC currents up to 2000A\u003c\/li\u003e\n\u003cli\u003eOutput terminal for recorder connection\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage, resistance measurement and continuity functions also available\u003c\/li\u003e\n\u003cli\u003eMinimum resolution 0.1A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse;width:100%\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC A\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e400\/2000A (0 to 1000A) ±1.5%rdg±2dgt [50\/60Hz] ±3%rdg±4dgt [40 to 500Hz] ±5%rdg±4dgt [500Hz to 1kHz] 2000A (1001 to 1999A) ±3%rdg±2dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDC A\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e400\/2000A ±1.5%rdg±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC V\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e400\/750V ±1.5%rdg±2dgt [50\/60Hz] ±1.5%rdg±4dgt [40Hz to 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDC V\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e400\/1000V ±1%rdg±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eΩ\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e400\/4000Ω ±1.5%rdg±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eContinuity buzzer\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eBuzzer sounds below 50±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eConductor size\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eØ55mm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eFrequency response\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e40Hz to 1kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eOutput\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eRecorder : DC400mV against AC\/DC400A DC200mV against AC\/DC2000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eSafety Standard\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V IEC 61010-031 , IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003ePower source\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eR6 (AA) (1.5V) × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e250(L) × 105(W) × 49(D)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eApprox. 530g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAccessories\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e7107A (Test leads) 9094 (Carrying Case) R6 (AA) × 2 , Instruction Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eOptional Accessories\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e7256 (Output cord)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eCatalog reference:\u003c\/strong\u003e KYORITSU General Catalog 2026, page 33\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/p\u003e\u003cp\u003eSpecifications and included accessories may be updated by the manufacturer. Please confirm compatibility and the required measurement category before use.\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":48061650305187,"sku":"20269131","price":52954.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/1271\/0563\/files\/kyoritsu-kew-2003a-acdc-clamp-meter-3108049.jpg?v=1788069247","url":"https:\/\/wafuu.com\/products\/kyoritsu-kew-2003a-ac-dc-clamp-meter-2003a","provider":"WAFUU JAPAN","version":"1.0","type":"link"}