{"product_id":"kyoritsu-kew-1062-digital-multimeter-1062","title":"KYORITSU KEW 1062 디지털 멀티미터 전문가용 True RMS 측정기","description":"\u003ch2\u003eKYORITSU KEW 1062 Digital Multimeter\u003c\/h2\u003e\u003cp\u003eProfessional electrical measuring instrument from KYORITSU Japan. The specifications below are based on the manufacturer's 2026 general catalog.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e0.02% basic DC accuracy\u003c\/li\u003e\n\u003cli\u003eLarge display with 50,000 counts\u003c\/li\u003e\n\u003cli\u003eDual display for double indication for AC and DC, V and Hz, etc.\u003c\/li\u003e\n\u003cli\u003eTrue-RMS Measurements AC and AC+DC\u003c\/li\u003e\n\u003cli\u003eWide AC Frequency bandwidth from 10Hz to 100kHz\u003c\/li\u003e\n\u003cli\u003eTrue-RMS or MEAN value detection mode can be selected\u003c\/li\u003e\n\u003cli\u003eFast Peak Hold response time of 250µs\u003c\/li\u003e\n\u003cli\u003eLow-pass filter for motor drive measurements\u003c\/li\u003e\n\u003cli\u003eLow Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current\u003c\/li\u003e\n\u003cli\u003eUser calibration function\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61010-1 CAT IV 600V, CAT III 1000V\u003c\/li\u003e\n\u003cli\u003eTerminal shutter to prevent incorrect test leads' insertion in current terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse;width:100%\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDetection mode\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eMEAN\/True RMS (switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDC V\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e50.000\/500.00\/2400.0mV\/5.0000\/50.000\/500.00\/1000.0V (Input impedance: Approx. 100MΩ [50\/500\/2400mV], 10MΩ [5\/50\/500\/1000V]) ±0.02%rdg±2dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC V [True RMS]\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e50.000\/500.00mV\/5.0000\/50.000\/500.00\/1000.0V (Input impedance: 11MΩ\u0026lt;50pF [50\/500mV\/5V], 10MΩ\u0026lt;50pF [50\/500\/1000V]) ±0.4%rdg±30dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC V [MEAN]\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e50.000\/500.00mV\/ 5.0000\/50.000\/500.00\/1000.0V (Input impedance:11MΩ\u0026lt;50pF [50\/500mV\/5V],10MΩ\u0026lt;50pF [50\/500\/1000V]) ±1%rdg±30dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDCV+ACV\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e5.0000\/50.000\/500.00\/1000.0V (Input impedance: 11MΩ\u0026lt;50pF [5V], 10MΩ\u0026lt;50pF [50\/500\/1000V]) ±0.5%rdg±10dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDC A\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.00\/5000.0µA\/50.000\/500.00mA\/5.0000\/10.000A ±0.2%rdg±5dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC A [True RMS]\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.00\/5000.0µA\/50.000\/500.00mA\/5.0000\/10.000A ±0.75%rdg±20dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAC A [MEAN]\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.00\/5000.0µA\/50.000\/500.00mA\/ 5.0000\/10.000A ±1.5%rdg±20dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDCA+ACA\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.00\/5000.0µA\/50.000\/500.00mA\/5.0000\/10.000A ±1%rdg±10dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eΩ\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.00Ω\/5.0000\/50.000\/500.00kΩ\/5.0000\/50.000MΩ ±0.05%rdg±2dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eLowPower-Ω\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e5.000\/50.00\/500.0kΩ\/5.000MΩ ±0.2%rdg±3dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eContinuity buzzer\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e500.0Ω (The buzzer turns on at resistances lower than 100±50Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDiode test\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e2.4000V ±1%rdg±2dgt Open curcuit voltage: \u0026lt;5V (Approx. 0.5mA Measuring Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eCapacitance\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e5.000\/50.00\/500.0nF\/5.000\/50.00\/500.0µF\/5.000\/50.00mF ±1%rdg±5dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e2.000 to 9.999\/9.00 to 99.99\/90.0 to 999.9Hz\/0.900 to 9.999\/9.00 to 99.99kHz ±0.02%rdg±1dgt (Basic accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDUTY\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e10 to 90% ±1%rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eTemperature\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e-200 to 1372ºC ±1%rdg±1.5ºC -328 to 2501.6ºF ±1%rdg±2.0ºF (with the use of K-type Temperature probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eMeasurement functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eDC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eOther functions\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eData Hold (D\/H), Auto Hold (A\/H), Peak Hold (P\/H), Range Hold (R\/H), Maximum value (MAX), Minimum value (MIN) Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eApplicable standards\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V Pollution degree 2 IEC 61010-031, IEC 61326-1 (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003ePower source\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eR6\/LR6 (1.5V)×4 (Auto power off: approx. 20 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eDimension\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e192(L)×90(W)×49(D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003eApprox. 570g (including batteries and blank cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eAccessories\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e7220A (Test leads) 8926 (Fuse [440mA\/1000V])×1 (included) 8927 (Fuse [10A\/1000V])×1 (included) Batteries Instruction manual B lank cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;padding:6px\"\u003eOptional accessories\u003c\/th\u003e\n\u003ctd style=\"padding:6px\"\u003e7234 (Alligator clip) 8241 (USB Communication set) 8115 (AC\/DC Clamp Sensor) 8121 (Load current Clamp Sensor) 8122 (Load current Clamp Sensor) 8123 (Load current Clamp Sensor) 8146 (Leakage \u0026amp; Load current Clamp Sensor) 8147 (Leakage \u0026amp; Load current Clamp Sensor) 8148 (Leakage \u0026amp; Load current Clamp Sensor) 7146 (Banana Ø4 adjuster plug) 8405 (Temperature probe) 8407 (Temperature probe) 8408 (Temperature probe) 9154 (Carrying case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eCatalog reference:\u003c\/strong\u003e KYORITSU General Catalog 2026, page 22,23\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/p\u003e\u003cp\u003eSpecifications and included accessories may be updated by the manufacturer. Please confirm compatibility and the required measurement category before use.\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":48061648208035,"sku":"20269121","price":121162.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/1271\/0563\/files\/kyoritsu-kew-1062-digital-multimeter-1933164.jpg?v=1788069247","url":"https:\/\/wafuu.com\/ko\/products\/kyoritsu-kew-1062-digital-multimeter-1062","provider":"WAFUU JAPAN","version":"1.0","type":"link"}